In what order do you test a permit space's atmosphere, and who gets to watch?

Quick answer

Oxygen first, then combustible gases and vapors, then toxic gases and vapors (29 CFR 1910.146(d)(5)(iii)). Conditions must be tested before entry is authorized (1910.146(d)(5)(i)) and tested or monitored as necessary during entry ((d)(5)(ii)). Each authorized entrant, or their representative, must be given the chance to observe the testing ((d)(5)(iv)) and may demand a reevaluation ((d)(5)(v)). Acceptable oxygen is 19.5 to 23.5 percent; outside that is a hazardous atmosphere (29 CFR 1910.146(b)).

The order is not a tradition; it is in the regulatory text, and there is a physical reason for it.

The sequence. When testing for atmospheric hazards, test first for oxygen, then for combustible gases and vapors, and then for toxic gases and vapors (29 CFR 1910.146(d)(5)(iii)). Most combustible-gas sensors need adequate oxygen to read correctly, and some toxic-gas readings are affected by both, so the sequence is what makes the later numbers trustworthy.

Before and during. The employer's permit program must test conditions in the space to determine whether acceptable entry conditions exist before entry is authorized, with a narrow allowance for spaces that cannot be isolated, such as sewers, where pre-entry testing is done to the extent feasible (29 CFR 1910.146(d)(5)(i)). The space must then be tested or monitored as necessary to determine that acceptable conditions are being maintained throughout the entry (29 CFR 1910.146(d)(5)(ii)).

The entrant's rights. Each authorized entrant, or that employee's authorized representative, must be given an opportunity to observe the pre-entry and any subsequent testing (29 CFR 1910.146(d)(5)(iv)), may request a reevaluation if they have reason to believe the evaluation was inadequate, which must then be done in their presence ((d)(5)(v)), and must be provided the results immediately on request ((d)(5)(vi)). The results, with the tester's initials and times, go on the permit (29 CFR 1910.146(f)(10)).

The numbers. A hazardous atmosphere includes oxygen below 19.5 percent or above 23.5 percent (29 CFR 1910.146(b)), a flammable gas, vapor or mist above 10 percent of its lower flammable limit, or a substance above its permissible exposure limit.

Entrants who have never been offered the chance to watch the meter are the quickest way to find out a program is paperwork.

29 CFR 1910.146(d)(5)(i)29 CFR 1910.146(d)(5)(ii)29 CFR 1910.146(d)(5)(iii)29 CFR 1910.146(d)(5)(iv)29 CFR 1910.146(d)(5)(v)29 CFR 1910.146(d)(5)(vi)29 CFR 1910.146(f)(10)29 CFR 1910.146(b)
Source: An analysis from the permit-required confined spaces standard, 29 CFR 1910.146. Primary reference: read it on osha.gov →

Federal rule shown. If the workplace is in one of the 29 State Plan states and territories, the state standard governs and may differ — see Known Limitations.

Need the passage itself?

Canary AI has indexed all of federal OSHA — 7,220 passages of 29 CFR and 279 interpretation letters — and finds the exact section for a question, with a link to the official text. Free, no sign-up, nothing collected.

Open the lookup tool →

Related answers

On a construction site, who has to identify confined spaces, and what happens once one is a permit space?Confined Spaces · standards analysisAre large product heating furnaces confined spaces if workers just step up into them?Confined Spaces · OSHA letter 2019-05-20Can employers review just a sample of confined space entry permits for the annual review?Confined Spaces · OSHA letter 2023-07-24